This section specifies the minimum permanent free opening area required for chimney dampers associated with unlisted decorative appliances installed in vented fireplaces. The requirements are detailed in Table 634.1, which outlines the necessary openings based on chimney height and appliance input rating. Applies to building owners installing decorative appliances in fireplaces.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

634.1 Free opening area of chimney dampers.

FGC § 634.1

Where an unlisted decorative appliance for installation in a vented fireplace is installed, the fireplace damper shall have a permanent free opening equal to or greater than specified in Table 634.1. Table 634.1Free Opening Area of Chimney Damper for Venting Flue Gasses from Unlisted Decorative Appliances for Installation in Vented Fireplaces Chimney Height(Feet)Minimum Permanent Free Opening (Square Inches) a8132029395164Appliance Input Rating (BTU Per Hour)Chimney Height(Feet)Minimum Permanent Free Opening (Square Inches) a8132029395164Appliance Input Rating (BTU Per Hour)67,80014,00023,20034,00046,40062,4008,00088,40015,20025,20037,00050,40068,00086,000109,00016,80027,60040,40055,80074,40096,400159,80018,20030,20044,60062,40084,000108,8002010,60020,20032,60050,40068,40094,000122,2003011,20021,60036,60055,20076,800105,800138,600 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 square inch = 645.16 m 2 , 1 British thermal unit per hour = 0.2931 W. a. The first six minimum permanent free openings (8 to 51 square inches) correspond approximately to the cross-sectional areas of chimneys having diameters of 3 through 8 inches, respectively. The 64-square-inch opening corresponds to the cross-sectional area of standard 8-inch by 8-inch chimney tile.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 634.1?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters