What is NYC FGC § 609.2?

Quick Answer

This section outlines the installation requirements for floor furnaces, including placement restrictions in doorways, stairways, and proximity to walls and draperies. It mandates accessibility and specific construction standards for floors. Applies to building owners installing floor furnaces in residential and commercial properties.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

609.2 Placement.

FGC § 609.2

The following provisions apply to floor furnaces: 1. Floors. Floor furnaces shall not be installed in the floor of any doorway, stairway landing, aisle or passageway of any enclosure, public or private, or in a means of egress from any such room or space.

2.Walls and corners. The register of a floor furnace with a horizontal warm-air outlet shall not be placed closer than 6 inches (152.4 mm) to the nearest wall. A distance of not less than 18 inches (457.2 mm) from two adjoining sides of the floor furnace register to walls shall be provided to eliminate the necessity of occupants walking over the warm-air discharge. The remaining sides shall be permitted to be placed not closer than 6 inches (152.4 mm) to a wall. Wall-register models shall not be placed closer than 6 inches (152.4 mm) to a corner.

3.Draperies. The furnace shall be placed so that a door, drapery or similar object cannot be nearer than 12 inches (304.8 mm) to any portion of the register of the furnace.

4.Floor construction. Floor furnaces shall be located so as to be readily accessible. Means shall be provided for supporting the furnace when the grille is removed. Floor furnaces shall be installed only on floors of noncombustible construction having at least a two-hour fire rating, except that floor furnace enclosures in one-and two- family dwellings shall be constructed of non-combustible materials with a fire-resistance rating of not less than one hour.

5.Thermostat. The controlling thermostat for a floor furnace shall be located within the same room or space as the floor furnace or shall be located in an adjacent room or space that is permanently open to the room or space containing the floor furnace.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 609.2?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters