What is NYC MC § 504.8.4.1?

Quick Answer

This section establishes the maximum allowable length for exhaust ducts connected to dryers, set at 35 feet. It specifies that the length must be adjusted based on the type of fittings used, as detailed in Table 504.8.4.1. Applies to building owners managing dryer exhaust systems.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

504.8.4.1 Specified length.

MC § 504.8.4.1

The maximum length of the exhaust duct shall be 35 feet (10 668 mm) from the connection to the transition duct from the dryer to the outlet terminal or to a common or central exhaust system. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with Table 504.8.4.1. Table 504.8.4.1Dryer Exhaust Duct Fitting Equivalent Length a Dryer Exhaust Duct Fitting Type Equivalent Length Dryer Exhaust Duct Fitting Type Equivalent Length 4" radius mitered 45-degree elbow2 feet 6 inches 4" radius mitered 90-degree elbow5 feet 6" radius smooth 45-degree elbow1 foot 6" radius smooth 90-degree elbow1 foot 9 inches 8" radius smooth 45-degree elbow1 foot 8" radius smooth 90-degree elbow1 foot 7 inches 10" radius smooth 45-degree elbow9 inches 10" radius smooth 90-degree elbow1 foot 6 inches For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 degree = 0.0175 rad. a. The equivalent length column of the table indicates how much length must be added to the exhaust duct total length for each fitting used.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 504.8.4.1?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters