What is NYC MC § 502.7.4?

Quick Answer

This section mandates that flammable vapor areas of dip tank operations must have mechanical ventilation sufficient to prevent hazardous vapor accumulation. The ventilation systems are required to be designed so that any failure of a ventilating fan will automatically halt the dipping conveyor system. Applies to operators of dip tank operations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

502.7.4 Dipping operations.

MC § 502.7.4

Flammable vapor areas of dip tank operations shall be provided with mechanical ventilation adequate to prevent the dangerous accumulation of vapors. Required ventilation systems shall be so arranged that the failure of any ventilating fan will automatically stop the dipping conveyor system.