What is NYC MC § 502.15?

Quick Answer

This section mandates that repair garages storing Class I liquids or LP-gas in basements or pits must have ventilation systems. The required ventilation rate is a minimum of 1.5 cubic feet per minute per square foot to prevent the accumulation of flammable vapors. Applies to building owners operating repair garages.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

502.15 Repair garages.

MC § 502.15

Where Class I liquids or LP-gas are stored or used within a building having a basement or pit wherein flammable vapors could accumulate, the basement or pit shall be provided with ventilation at a minimum rate of 1.5 cubic feet per minute per square foot (cfm/ft2) (0.008 m 3 /(s • m 2 )) designed to prevent the accumulation of flammable vapors therein.