What is NYC FGC § 504.2.6?

Quick Answer

This section addresses the vent capacity requirements for appliances with multiple input rates. The minimum vent capacity must be less than the lowest appliance input rating, while the maximum vent capacity must exceed the highest appliance input rating. Applies to building owners operating multiple input rate appliances.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

504.2.6 Multiple input rate appliances.

FGC § 504.2.6

For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest appliance input rating, and the maximum vent capacity (FAN Max/NAT Max) determined from the tables shall be greater than the highest appliance rating input.