What is NYC FGC § 503.10.8?

Quick Answer

This section establishes the maximum horizontal lengths for vent connectors, specifying that a single-wall connector can be 75 percent of the chimney or vent height, while a Type B double-wall connector can be 100 percent, both excluding engineered systems. Applies to building owners and operators of vented systems.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

503.10.8 Length of vent connector.

FGC § 503.10.8

The maximum horizontal length of a single-wall connector shall be 75 percent of the height of the chimney or vent except for engineered systems. The maximum horizontal length of a Type B double-wall connector shall be 100 percent of the height of the chimney or vent except for engineered systems.