What is NYC FGC § 503.10.4.1?

Quick Answer

This section outlines the requirements for openings into a chimney flue or vent when two or more are provided. Openings must be at different levels or the connectors should be attached at an angle of 45 degrees or less to the vertical. Applies to building owners managing chimney systems.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

503.10.4.1 Two or more openings.

FGC § 503.10.4.1

Where two or more openings are provided into one chimney flue or vent, the openings shall be at different levels, or the connectors shall be attached to the vertical portion of the chimney or vent at an angle of 45 degrees (0.79 rad) or less relative to the vertical in accordance with Figure 503.10.4.1. Figure 503.10.4.1Opposing Openings in Chimney