This section specifies the required clearance measurements for furnace plenums adjacent to plaster on metal lath or noncombustible materials attached to combustible materials. The clearance must be measured to the surface of the plaster or other noncombustible finish when the specified clearance is 2 inches or less. Applies to building owners and operators managing furnace installations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

308.4.4 Plenum clearances.

FGC § 308.4.4

Where the furnace plenum is adjacent to plaster on metal lath or noncombustible material attached to combustible material, the clearance shall be measured to the surface of the plaster or other noncombustible finish where the clearance specified is 2 inches (50.8 mm) or less.