This section outlines the types of equipment that do not require venting according to reference standard RS 15-2. It includes various appliances such as ranges, built-in cooking units, hot plates, and certain water heaters. Applies to building owners utilizing specified equipment in residential and commercial settings.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-880 Equipment not required to be vented.

AC § 27-880

(a)Ranges for which a vent is not required by reference standard RS 15-2.

(b)Built-in domestic cooking units for which a vent is not required by reference standard RS 15-2.

(c)Hot plates and laundry stoves.

(d)Type 1 clothes dryers. (*e) Water heaters with inputs not over five thousand Btu/hr. (See note below.) (*f) Automatically controlled instantaneous water heaters that supply water to a single faucet which is attached to and made a part of the equipment. (*g) A single booster type (automatic instantaneous) water heater when designed and used solely for the sanitizing rinse requirements of a national sanitation foundation class one, two or three dishwashing machine, provided that the input is limited to fifty thousand Btu/hr. the storage capacity is limited to twelve and one-half gallons and the heater is installed in a commercial kitchen having a mechanical exhaust system. (*h) Refrigerators. (*i) Counter equipment. (*j) Room heaters for which a vent is not required by reference standard RS 15.0. (*k) Other equipment for which a vent is not required and which are not provided with flue collars. (*l) Specialized equipment of limited input such as laboratory burners or gas lights. * Note: When any, or all, of the equipment marked with an asterisk (*) is installed so that the aggregate input rating exceeds thirty Btu/hr. per cubic foot of room or space in which it is installed, one or more pieces of the equipment shall be provided with a venting system or other equivalent means for removing the vent gases to the outdoor air so that the aggregate input rating of the remaining unvented equipment does not exceed the thirty Btu/hr. per cubic foot figure. When the room or space in which such equipment is installed is directly connected to another room or space by a doorway, archway, or other opening of comparable size, which cannot be closed, the volume of such adjacent room or space may be included in the calculations.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-880?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters