This section outlines the requirements for factory-built chimneys in residential and other occupancy groups, specifying that they must be listed and accepted according to various reference standards. It also details enclosure requirements and height limitations for chimneys servicing factory-built fireplaces or wood-burning stoves. Applies to building owners of residential and commercial properties with such installations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-869.01 Factory-built chimneys.

AC § 27-869.01

(a)Residential occupancy. In residential occupancy groups J-2 and J-3: (1) Factory-built chimneys servicing liquid or gas fueled appliances shall be listed and accepted in accordance with reference standard RS 15-8.

(2)Factory-built chimneys servicing wood burning fireplaces or stoves and inserts shall be listed and accepted in accordance with reference standards RS 15-9, RS 15-10, RS 15-12 or RS 15-15.

(3)Factory-built chimneys servicing factory-built fireplaces shall be listed and accepted in accordance with reference standard RS 15-15.

(b)Other occupancies. In all other occupancy groups: (1) Factory-built chimneys servicing liquid or gas fueled appliances shall be listed and accepted in accordance with reference standard RS 15-10 or RS 15-11.

(c)Enclosures. All factory-built chimneys shall be enclosed in accordance with the requirements of table 15-3.

(d)Height limitation: Every chimney servicing a factory-built fireplace or wood burning stove in a building of more than seventy-five feet in height shall be listed and accepted in accordance with reference standard RS 15-10, unless such chimney is an unlisted high temperature chimney constructed in accordance with the requirements of section 27-861 and of table 15-6 of subdivision (c) of section 27-863, and is installed to serve the appliance.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-869.01?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters