This section outlines the construction requirements for unlisted chimneys used with low, medium, and high temperature equipment, specifying materials, thicknesses, and lining requirements for each type. The Department of Buildings enforces these regulations. Applies to building owners and operators involved in chimney construction and maintenance.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-863 Chimney construction for low, medium, and high temperature equipment.

AC § 27-863

(a)Unlisted chimneys for low temperature equipment shall be constructed in accordance with table 15-4.

(b)Unlisted chimneys for medium temperature equipment shall be constructed in accordance with table 15-5.

(c)Unlisted chimneys for high temperature equipment shall be constructed in accordance with table 15-6. Table 15-4Low Temperature Chimney Construction MaterialThicknessLining RequiredType of LiningThicknessAir SpaceSteel a (for exterior chimneys) b 1/8 in. for areas up to 7 sq. ft., 3/16 in. for areas up to 12.5 sq. ft., 1/4 in. for larger.Not required. . . .. . . .. . . .Steel a (for interior chimneys)No. 16 U.S. gauge for areas up to 155 sq. in., No. 14 U.S. gauge up to 200 sq. in., No. 12 U.S. gauge up to 255 sq. in., No. 10 U.S. gauge for greater areas.Not required. . . .. . . .. . . .Brick, masonry units, or 8.c in stone Full height from chimney base to 4 in. above chimney wall.Clay flue lining meeting requirements of Reference Standard RS 15-4, with fire clay mortar or cement mortar equal to that of Type M or Ref. Std. RS 15-3, or a heatproof and acidproof flue lining joint cement.Not less than 5/8 in.Not less than 1/4 in. nor more than 3/4 in. between chimney walls and flue liningConcreteRadial Brick6 in. c7 1/2 in.dittoFull height from chimney base to 4 in. above chimney wall.dittoFirebrick Type G, RS 15-6, 4 1/2 in. laid in medium refractory mortar, RS 15-7, or acid resistant brick Type H or L, Ref. Std. RS 15-8ditto. . . .ditto. . . .Brick type H or L, RS 15-78 in.Not required. . . .. . . .. . . . Notes for Table 15-4: a. Metal Chimneys shall be riveted, bolted or welded construction and made gas tight. b. Exterior metal chimneys shall be galvanized, or pained on the exterior surface with a heat resisting paint or be constructed of equal corrosion alloys. c. In buildings in residential occupancy group J-3, of four stories or less, and in other buildings not over two stories high and not in high hazard occupancy group A, providing the flue areas are not more than 200 sq. in., the walls of masonry or concrete chimneys may be reduced to 4 in. with fire clay flue linings. Flue linings shall be set ahead of chimney walls, and carefully bedded in fire clay mortar or in cement mortar. Chimney walls shall be provided with mortar spacer ties every 10 ft. of height. Mortar ties shall not be continuous around the flue linings. Table 15-5Medium Temperature Chimney Construction MaterialThicknessLining RequiredType of LiningThicknessAir SpaceSteelSame as for low temp. chimneyLining is required for full height of chimneyIncinerators only – Castable refractory Cl A, RS 15-52 in.None requiredMedium-duty fireclay refractory brick (ASTM C 64) or the equivalent laid in medium- duty refractory mortar (ASTM C 105) or the equivalent, RS 15-6The lining shall be at least 2 1/2 in. thick for chimneys having a diameter or greatest cross- section dimension of 18 in. or less. The lining shall have a thickness of not less than 4 1/2 in. laid on a full bed for chimney having a diameter or greatest cross- section dimension greater than 18 in. Table 15-6High Temperature Chimney Construction MaterialThicknessLining RequiredType of LiningThicknessAir SpaceSteelSame as for low temperature chimneysFor full height of chimneyHigh-duty fireclay brick (ASTM C 64) or the equivalent not less than 4 1/2 in. thick laid on a full width bed in high-duty refractory mortar (ASTM C 105) or the equivalent, RS 15-64 1/2 inchesNone required

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-863?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters