Brooklyn since 2014All five boroughsSame-day response during business hours

What is NYC AC § 27-563?

Quick Answer

This section outlines the design requirements for structural members under partial loading conditions in continuous framing and cantilever construction. It specifies how to account for live loads and their arrangements to ensure maximum stress is considered. Applies to building owners involved in structural design and construction.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-563 Partial loading conditions.

AC § 27-563

(a)Uniformly distributed loads. In continuous framing and cantilever construction, the design shall consider live load on all spans and arrangements of partial live load that will produce maximum stresses in the supporting members. The simplifications given in paragraphs one through three of this subdivision are permissible.

(1)FLOOR AND ROOF FRAMING. a. For vertical live load applied to the level under consideration, the far ends of the columns above and below that level may be assured as fixed. b. Combinations of live load may be limited to the following: 1. Live load placed on two adjacent spans.

2.Live load placed on alternate spans. The effects of live load on spans more than two spans away from the span under consideration may be neglected.

(2)ARCHES AND GABLED FRAMES. a. Live load placed on 1/2 span adjacent to one support. b. Live load placed on the center 1/4 span. c. Live load placed on 3/8 the span adjacent to each support.

(3)COLUMNS. Moments due to vertical loads may be calculated from the live load on the largest single adjacent span of the floor under consideration. This moment shall be assumed to act concurrently with live load on all other floors.

(b)Moving concentrated loads. Structural members supporting moving concentrated loads shall be designed for only those loads that can physically occur simultaneously and are arranged to produce maximum stresses.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-563?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters