§ 27-511 Separation.
AC § 27-511
No tent or air-supported structure shall be erected closer than twenty feet to any interior lot line nor closer than thirty feet in any direction to an unprotected opening, required exterior stairway or corridor, or required exit door, on the same level or above the level of the tent or air-supported structure. A tent or air-supported structure may abut another building on the same lot if there are no unprotected openings or exits above or within thirty feet as above stipulated, if there is no door between them that is a required exit, and if the exterior wall separating them meets the requirements of subchapter five of this chapter for fire divisions. Exceptions. Requirements for separation from other buildings on the site shall be waived where a tent or air-supported structure is used for on-site temporary shelter for construction work, or incidental fabrication of construction elements to be used on the site of construction.