This section outlines the construction and design requirements for fire escapes on existing buildings, including specifications for capacity, stairs, landings, handrails, and access. The statute mandates compliance with safety standards and materials. Applies to building owners responsible for fire escape installations and alterations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-380 Fire escapes.

AC § 27-380

Fire escapes constructed on existing buildings when altered or as a second means of egress for group homes as permitted by section 27-368 of this article shall comply with the following: (a) Capacity. The capacity of fire escapes shall be as listed in table 6-1 for stairs.

(b)Stairs. The minimum width of fire escape stairs shall be twentytwo inches. Treads shall have a minimum width of eight inches, exclusive of a required one inch nosing. The maximum height of risers shall be eight inches. No flight of stairs shall exceed twelve feet in height between landings.

(c)Landings. Landings shall be provided at each story served by fire escapes. The minimum width of landings shall be three feet, and the minimum length shall be four feet six inches. Floor openings in landings shall be at least twenty-two inches by twenty-eight inches.

(d)Handrails and guards. Handrails having a minimum height of thirty-two inches above the tread nosing shall be provided on both sides of stairs, and guards having a minimum height of thirty-six inches shall be provided on all open sides of landings, openings in guards shall be of such dimensions as to prevent the passage of a five inch dia. ball.

(e)Construction. Fire escapes shall be constructed of noncombustible materials adequately protected against deterioration by corrosion or other effects of exposure to the weather, and shall be designed to comply with the requirements of subchapter nine of this chapter.

(f)Access. Access to fire escapes shall be by doors or windows having a minimum clear opening of twenty-four inches in width and thirty inches in height. Such doors or windows shall have a fire protection rating of three-quarters of an hour except in buildings classified in occupancy group J-2.

(g)Discharge. The top landing of fire escapes shall be provided with a stair or gooseneck ladder leading to the roof, except that this requirement shall not apply to buildings having a roof pitch of more than twenty degrees. The lowest landing of fire escapes shall be not more than sixteen feet above grade and shall be provided with a stair to grade which may be counterbalanced.

Common Questions

Our team

Meet the people you will work with

TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB
TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB

Free case review

Have a matter that touches § 27-380?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

reception@nacmiaslaw.com

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters