What is NYC AC § 27-365?

Quick Answer

This section mandates that rooms or enclosed spaces with occupant loads exceeding specified limits must have at least two remote door openings leading to exits. Additionally, it outlines requirements for door openings in certain dwelling units based on building height and occupancy classification. Applies to building owners of multi-family dwellings and commercial spaces.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-365 Egress from rooms and spaces.

AC § 27-365

(a)There shall be at least two door openings, remote from each other and leading to exits, from every room or enclosed space in which the total occupant loads exceeds the number of persons listed in table 6-3. TABLE 6-3Maximum Occupant Load-Spaces With One DoorMax. Occupant Load Occupancy Group ClassificationMax. Occupant Load With One DoorA 10 B 50 C 75 D 50 E 75 F 75 G 75 H 15 J 20 (b) Except as otherwise provided for in subdivisions (c) and (d) of this section, in buildings of combustible construction group II exceeding two stories in height there shall be at least two door openings from each J-1 or J-2 dwelling unit which shall be remote from each other. Each door opening shall lead to separate exits either directly or by separate corridors or one door opening shall lead to an exit and the other to a balcony complying with subdivision (g) of section 27-369 of article five of this subchapter.

(c)In buildings or spaces classified in occupancy group J-2 not more than three stories and forty feet in height, occupied by not more than four families on each story and of combustible construction group II there shall be at least two door openings from each J-2 dwelling unit which shall be remote from each other. One door opening shall lead to an exit and the other to a balcony complying with subdivision (g) of section 27-369 of article five of this subchapter.

(d)Buildings not exceeding three stories in height and occupied exclusively by not more than one family on each story without boarders, roomers or lodgers are exempt from the provisions of subdivisions (b) and (c) of this section.

Common Questions

Our team

Meet the people you will work with

TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB
TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB

Free case review

Have a matter that touches § 27-365?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

reception@nacmiaslaw.com

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters