This section mandates fire protection measures for old law tenements based on their height. It specifies requirements for self-closing doors, fire-retardant ceilings, and fire resistance ratings for apartment doors. The Department of Buildings enforces these regulations, which apply to building owners of old law tenements.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-2044 Fire protection in certain old law tenements.

AC § 27-2044

a. In every old law tenement which is less than four stories in height: (1) Every door opening into any entrance hall or stair, or into any public hall connected therewith, shall be self-closing; every glazed opening or glazed panel in such a door shall be glazed with wire glass, and every transom opening upon any public hall shall be glazed with wire glass firmly secured in a closed position; and (2) Every interior sash, or opening other than a door, in the walls or partitions of any such hall, and every window in any such hall not opening to the outer air, shall be removed and the openings closed up and fire-retarded; and (3) The ceiling of the cellar, or if there is no cellar, of the basement or other lowest story, shall be fire-retarded unless such ceiling already has been plastered or covered in a manner satisfactory to the department with plasterboard or gypsumboard at least one-half inch in thickness. b. In every old law tenement which is four stories or more in height: (1) On all stories above the third story, every apartment door opening into any stair or into any public hall connected therewith, unless such stair or public hall is protected by an approved sprinkler system shall have a fire resistance rating of at least one hour. Existing door frames in good condition may be retained. All such doors shall comply with this requirement, not later than November second, nineteen hundred seventy-three.

(2)For all stories below the fourth story, any application for an alteration permit for alterations to be made in an apartment below the fourth story shall include the provision that every door of such apartment opening into any entrance hall, stair or into any public hall connected therewith, unless such entrance hall, stair or public hall is protected by an approved sprinkler system, shall have a fire resistance rating of at least one hour. Existing door frames in good condition may be retained.

(3)Where apartment doors having a fire resistance rating of at least one hour are required, every transom opening upon any entrance hall, stair or public hall connected therewith shall be sealed and fireretarded. All other transoms opening upon any entrance hall, stair or public hall connected therewith shall be glazed with wire glass and permanently sealed in a closed position.

(4)All doors opening into any entrance hall, stair or into any public hall connected therewith shall be self-closing; every glazed opening or glazed panel in such a door shall be glazed with wire glass.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-2044?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters