This section outlines the maximum developed length and minimum pipe diameters for individual branch fixture vents and individual fixture header vents, based on specified airflow rates. The Department of Buildings enforces these regulations. Applies to building owners and property operators managing plumbing systems.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

919.2 Individual branch fixture and individual fixture header vents.

PC § 919.2

The maximum developed length of individual fixture vents to vent branches and vent headers shall be determined in accordance with Table 919.2 for the minimum pipe diameters at the indicated vent airflow rates. The individual vent airflow rate shall be determined in accordance with the following: Qh,b = Nn,bQv (Equation 9-1) For SI: Qh,b = Nn,bQv(0.4719 L/s) where: Nn,b = Number of fixtures per header (or vent branch) ÷ total number of fixtures connected to vent stack. Qh,b = Vent branch or vent header airflow rate (cfm). Qv = Total vent stack airflow rate (cfm). Qv(gpm) = 27.8rs2/3 (1 - rs)D8/3 Qv(cfm) = 0.134Qv (gpm) where: D = Drainage stack diameter (inches). Qw = Design discharge load (gpm). rs = Waste water flow area to total area. = Qw / 27.8D8/3 Individual vent airflow rates are obtained by equally distributing Qh,b into one-half the total number of fixtures on the branch or header for more than two fixtures; for an odd number of total fixtures, decrease by one; for one fixture, apply the full value of Qh,b. Individual vent developed length shall be increased by 20 percent of the distance from the vent stack to the fixture vent connection on the vent branch or header. Table 919.2Minimum Diameter and Maximum Length of Individual Branch Fixture Vents and Individual Fixture Header Vents for Smooth Pipes Diameter of Vent Pipe (inches)Individual Vent Airflow Rate (cubic feet per minute)Maximum developed length of vent (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516171819 20Diameter of Vent Pipe (inches)Individual Vent Airflow Rate (cubic feet per minute)Maximum developed length of vent (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516171819 201/2952513854321111111111113/4 10088473020151097654333222211 ——10094654837292420171412119877661 1/4———————1008773625346403632292623211 1/2 ———————————10096847565605449452 ———————————————————100 For SI: 1 inch = 25.4 mm, 1 cubic foot per minute = 0.4719 L/s, 1 foot = 304.8 mm

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 919.2?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters