What is NYC PC § 906.5.2?

Quick Answer

This section specifies the requirements for the air pressure relief pipe connected to pneumatic sewage ejectors. It mandates that the pipe must terminate through the roof and be sized to relieve air pressure to atmospheric levels, with a minimum diameter of 1 1/2 inches. Applies to building owners utilizing pneumatic sewage ejectors.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

906.5.2 Pneumatic sewage ejectors.

PC § 906.5.2

The air pressure relief pipe from a pneumatic sewage ejector shall be connected to an independent vent stack terminating as required for vent extensions through the roof. The relief pipe shall be sized to relieve air pressure inside the ejector to atmospheric pressure, but shall be not less than 1 1/2 inches (38 mm) in size.