808.1.1.1 Suspended acoustical ceilings.
BC § 808.1.1.1
Acoustical ceilings that are to be suspended below floor or roof construction by means of a framing system shall consist of supporting hangers of minimum 1/4-inch diameter (6.4 mm) steel rods, carrying channels of minimum 1 1/2-inch deep (38.1 mm) cold-rolled steel weighing 0.440 pounds per linear foot (0.681 kg/m), and a supporting grid complying with Appendix R. Use of wire hangers shall not be permitted. Direct hung suspension systems shall not be permitted. Exception: Acoustical ceiling systems in Groups R-2 and R-3 occupancies shall be permitted to be installed in accordance with ASTM C 635 and ASTM C 636 without modifications.