716.5 Fire door and shutter assemblies.
BC § 716.5
Approved fire door and fire shutter assemblies shall be constructed of any material or assembly of component materials that conforms to the test requirements of Section 716.5.1, 716.5.2 or 716.5.3 and the fire protection rating indicated in Table 716.5. Fire door frames with transom lights, sidelights or both shall be permitted in accordance with Section 716.5.6. Fire door assemblies and shutters shall be installed in accordance with the provisions of this section and NFPA 80. Exceptions: 1. Labeled protective assemblies that conform to the requirements of this section or UL 10A, UL 14B and UL 14C for tin-clad fire door assemblies.
2.Floor fire door assemblies in accordance with Section 712.1.13.1. Table 716.5Opening Fire Protection Assemblies, Ratings and Markings Type of AssemblyRequired Wall Assembly Rating(Hours)Minimum Fire Door and Fire Shutter Assembly Rating(Hours)Door Vision Panel Size bFire-Rated Glazing MarkingDoor Vision Panel dMinimum Sidelight / Transom Assembly Rating (Hours)Fire-Rated Glazing Marking Sidelight / Transom PanelFire protectionFire resistanceFire protectionFire resistanceType of AssemblyRequired Wall Assembly Rating(Hours)Minimum Fire Door and Fire Shutter Assembly Rating(Hours)Door Vision Panel Size bFire-Rated Glazing MarkingDoor Vision Panel dMinimum Sidelight / Transom Assembly Rating (Hours)Fire-Rated Glazing Marking Sidelight / Transom PanelFire protectionFire resistanceFire protectionFire resistanceFire walls, public corridor walls and fire barriers having a required fire-resistance rating greater than 1 hour43See Note bD-H-W-240Not Permitted4Not PermittedW-24033 aSee Note bD-H-W-180Not Permitted3Not PermittedW-18021 1/2100 sq. in.≤ 100 sq. in. = D-H-90>100 sq. in. = D-H-W-90Not Permitted2Not PermittedW-1201 1/21 1/2100 sq. in.≤ 100 sq. in. = D-H-90>100 sq. in. = D-H-W-90Not Permitted1 1/2Not PermittedW-90Enclosures for shafts, interior exit stairways and interior exit ramps21 1/2100 sq. in.≤ 100 sq. in. = D-H-90> 100 sq. in. = D-H-T-W-90Not Permitted2Not PermittedW-120Horizontal exits in fire walls e43100 sq. in.≤ 100 sq. in. = D-H-180> 100 sq. in. = D-H-W-240Not Permitted4Not PermittedW-24033 a100 sq. in.≤ 100 sq. in. = D-H-180> 100 sq. in. = D-H-W-180Not Permitted3Not PermittedW-180Fire barriers having a required fire-resistance rating of 1 hour: Enclosures for shafts, exit access stairways, exit access ramps, interior exit stairways and interior exit ramps; and exit passageway walls11100 sq. in. c≤ 100 sq. in. = D-H-60> 100 sq. in. = D-H-T-W-60Not Permitted1Not PermittedW-60Other fire barriers; and public corridor walls13/4Maximum size testedD-HFire protectionD-H3/4Fire partitions:Interior corridor walls13/4Maximum size testedD-203/4 bD-H-OH-45Other fire partitions13/4Maximum size testedD-H-453/4D-H-45Exterior walls31 1/2100 sq. in. b≤ 100 sq. in. = D-H-90> 100 sq. in = D-H-W-9021 1/2100 sq. in. b≤ 100 sq. in. = D-H-90> 100 sq. in.= D-H-W-9013/4Maximum size testedD-H-45Fire protectionD-H-453/4Smoke barriers11/3Maximum size testedD-20Fire protectionD-H-OH-453/4 For SI: 1 square inch = 645.2 mm. a. Two doors, each with a fire protection rating of 1 1/2 hours, installed on opposite sides of the same opening in a fire wall, shall be deemed equivalent in fire protection rating to one 3-hour fire door. b. Fire-resistance-rated glazing tested to ASTM E 119 in accordance with Section 716.2 shall be permitted, in the maximum size tested. c. Except where the building is equipped throughout with an automatic sprinkler and the fire-rated glazing meets the criteria established in Section 716.5.5. d. Under the column heading "Fire-rated glazing marking door vision panel", W refers to the fire-resistance rating of the glazing, not the frame. e. See Section 716.5.8.1.2.1.