What is NYC BC § 713.12.1.2?

Quick Answer

This section specifies the minimum effective venting area for smoke vents, requiring it to be at least 3.5% of the maximum shaft area on any floor, with a minimum of 72 square inches. Applies to building owners responsible for smoke vent installations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

713.12.1.2 Smoke vent dimensions.

BC § 713.12.1.2

The effective venting area shall be not less than 3 1/2 percent of the maximum shaft area at any floor, but in no event less than 72 square inches (46 451.5 mm 2 ).