This section mandates that grease interceptors must have devices to control the rate of water flow, ensuring it does not exceed the rated flow. The flow-control device must be vented and positioned appropriately above the flood rim level or installed per the manufacturer's specifications. Applies to property operators managing grease interceptors.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1003.3.4.2 Rate of flow controls.

PC § 1003.3.4.2

Grease interceptors shall be equipped with devices to control the rate of water flow so that the water flow does not exceed the rated flow. The flow-control device shall be vented and terminate not less than 6 inches (152 mm) above the flood rim level or be installed in accordance with the manufacturer's instructions.