503.2.8.1 Design requirements.
FC § 503.2.8.1
Gates across a fire apparatus access road shall comply with the following requirements: 1. The gates shall not encroach upon or otherwise reduce the required or approved width of a fire apparatus access road.
2.Gates shall be of the swinging or sliding type.
3.Manually-operated gates shall be designed to allow for operation by one person.
4.Only approved locking devices shall be used.
5.Manually-operated gates shall not be locked with a padlock or chain and padlock unless the padlock and chain are capable of being cut with standard bolt cutters.
6.Automatically-operated gates shall be designed and installed in accordance with ASTM F 2200 and UL 325, as applicable, and shall have an approved means of manual operation for emergency access by firefighters and other emergency response personnel.