Brooklyn since 2014All five boroughsSame-day response during business hours

What is NYC FC § 5003.11.1?

Quick Answer

This section establishes the maximum allowable quantities of nonflammable solid and nonflammable or noncombustible liquid hazardous materials that can be stored in control areas of Group M and S occupancies. It specifies limits based on material classification and conditions such as the presence of sprinkler systems. Applies to building owners managing hazardous materials in commercial spaces.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

5003.11.1 Maximum allowable quantity per control area in Group M or S occupancies.

FC § 5003.11.1

The aggregate amount of nonflammable solid and nonflammable or noncombustible liquid hazardous materials stored and displayed within a single control area of a Group M occupancy or stored in a single control area of a Group S occupancy shall not exceed the amounts set forth in FC Table 5003.11.1. FC Table 5003.11.1Maximum Allowable Quantity per Indoor and Outdoor Control Area in Group M and S OccupanciesNonflammable Solids, Nonflammable and Noncombustible Liquids d, e, f ConditionMaximum Allowable Quantityper Control AreaMaterial aClassSolidspoundsLiquidsgallonsConditionMaximum Allowable Quantityper Control AreaMaterial aClassSolidspoundsLiquidsgallonsHealth-Hazard Materials – Nonflammable and Noncombustible Solids and LiquidsCorrosives b, c Not Applicable9,750975Highly toxicsNot Applicable20 b, c2 b, cToxics b, cNot Applicable1,000100Physical-Hazard Materials – Nonflammable and Noncombustible Solids and LiquidsOxidizers b, c 4Not AllowedNot Allowed31,150 g11522,250 h225118,000 i, j1,800 i, jNondetonable unstable(reactives) b, c 4Not AllowedNot Allowed35505521,1501151Not LimitedNot LimitedNondetonable water-reactives3 b, c550552 b, c1,1501151Not LimitedNot Limited For SI: 1 pound = 0.454 kg, 1 gallon = 3.785 L, 1 cubic foot = 0.02832 m3. a. Hazard categories are as specified in FC 5001.2.2. b. Maximum allowable quantities shall be increased 100 percent in buildings protected throughout by a sprinkler system. When Note c applies, amounts increased shall be as set forth in both notes. c. Maximum allowable quantities shall be increased 100 percent when stored in approved storage cabinets in accordance with FC 5003.8. When Note b applies, amounts increased shall be as set forth in both notes. d. See FC Table 5003.8.3.3 for design and number of control areas. e. Maximum allowable quantities for other hazardous material categories shall be in accordance with FC 5003.1. f. Maximum allowable quantities shall be increased 100 percent in outdoor control areas. g. Maximum allowable quantities may be increased to 2,250 pounds when individual packages are in the original sealed containers from the manufacturer or packager and do not exceed 10 pounds each. h. Maximum allowable quantities may be increased to 4,500 pounds when individual packages are in the original sealed containers from the manufacturer or packager and do not exceed 10 pounds each. i. Quantities are unlimited where protected by a sprinkler system. j. Quantities are unlimited in an outdoor control area.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 5003.11.1?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters