What is NYC FC § 2306.2.1.3?

Quick Answer

This section outlines the design and construction requirements for underground liquid motor fuel storage tanks. It specifies that tanks must be double-walled and capable of containing any leakage, withstand maximum operating loads, and meet certain pressure standards. Applies to building owners managing fuel storage facilities.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2306.2.1.3 Tank design and construction.

FC § 2306.2.1.3

Underground liquid motor fuel storage tanks shall be designed and constructed in accordance with the following: 1. Tanks shall be completely double-walled and constructed of steel, fiberglass-reinforced plastic or a combination of both materials. The secondary tank shall be capable of containing any leakage from the primary tank.

2.Tanks shall be designed and constructed to withstand one and one-half times the maximum operating loads and stresses, regardless of the amount of liquid motor fuel contained in the tank. Such capabilities shall be established by buoyancy calculations and load and stress analyses.

3.Tanks shall be designed and constructed to withstand a pressure of 15 pounds per square inch gauge (psig) (103.4 kPa) or one and one-half times the maximum anticipated static head pressure, whichever is greater, for the primary tank and 5 pounds per square inch gauge (psig) (34.5 kPa) for the secondary tank.

4.The capacity of each individual tank shall not exceed 12,000 gallons (45 420 L) of liquid motor fuel.

Common Questions

Our team

Meet the people you will work with

TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB
TI

Tiffany Irizarry

Legal Coordinator

OATH / DOB

Free case review

Have a matter that touches § 2306.2.1.3?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

reception@nacmiaslaw.com

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters