This section outlines the requirements for separated occupancies in buildings, specifying the necessary separation times between different occupancy types. The statute includes a table detailing separation hours based on occupancy classifications and conditions related to fire safety systems. Applies to building owners managing mixed-use properties with varied occupancy types.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

508.4 Separated occupancies.

BC § 508.4

Buildings or portions of buildings that comply with the provisions of this section shall be considered as separated occupancies. Table 508.4Required Separation of Occupancies (Hours) OccupancyA, E I-1 a , I-3,I-4 I-2 RaF-2, S-2 b, U B c F-1 M S-1 H-1 H-2 H-3, H-4 H-5 SNSSNSSNSSNSSNSSNSSNSSNSSNSSNSSNSSNSSNSA, ENN122NP12N f1 f12121212NPNP34232NPI-1 a , I-3, I-4––NN2NP1NP1212121212NPNP3NP2NP2NPI-2––––NN2NP2NP2NP2NP2NP2NPNPNP3NP2NP2NPR a––––––NN1 c2 c 12121212NPNP3NP2NP2NPF-2, S-2 b, U––––––––NN12121212NPNP34232NPB e––––––––––NN231223NPNP23121NPF-1––––––––––––NN2323NPNP23121NPM––––––––––––––NN23NPNP23121NPS-1––––––––––––––––NNNPNP23121NPH-1––––––––––––––––––NNPNPNPNPNPNPNPH-2––––––––––––––––––––NNP1NP1NPH-3, H-4––––––––––––––––––––––1 d NP1NPH-5––––––––––––––––––––––––NNP S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. NS = Buildings not equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. N = No separation requirement. NP = Not permitted. a. See Section 420. b. The required separation from areas used only for private or pleasure vehicles shall be reduced by 1 hour but to not less than 1 hour. c. See Section 406.3.4. d. Separation is not required between occupancies of the same classification. e. See Section 422.2 for ambulatory care facilities. f. A commercial kitchen in Group F-2 that does not comply with Section 508.1, Exception 5 shall be separated from adjoining dining spaces with 1-hour fire separation where the dining spaces are equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1, and separated with 2-hour fire separation where the dining spaces is not equipped throughout with an automatic sprinkler system.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 508.4?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters