What is NYC BC § 506.3.2?

Quick Answer

This section establishes the minimum frontage distance required for an area factor increase based on the proximity of public ways or open spaces to a building's perimeter. It specifies that this distance must be at least 20 feet, with specific calculations for varying widths. Applies to building owners seeking area factor increases based on frontage measurements.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

506.3.2 Minimum frontage distance.

BC § 506.3.2

To qualify for an area factor increase based on frontage, the public way or open space adjacent to the building perimeter shall have a minimum distance (W) of 20 feet (6096 mm) measured at right angles from the building face to any of the following: 1. The closest interior tax lot line.

2.The entire width of a street, alley or public way.

3.The exterior face of an adjacent building on the same tax lot. Where the value of W is greater than 30 feet (9144 mm), a value of 30 feet (9144 mm) shall be used in calculating the building area increase based on frontage, regardless of the actual width of the public way or open space. Where the value of W varies along the perimeter of the building, the calculation performed in accordance with Equation 5-5 shall be based on the weighted average calculated in accordance with Equation 5-4. W = (L1 × w1 + L2 × w2 + L3 × w3 …)/F (Equation 5-4) where: W = (Width: weighted average) = Calculated width of public way or open space (feet). Ln = Length of a portion of the exterior perimeter wall. wn = Width (≥ 20 feet) of a public way or open space associated with that portion of the exterior perimeter wall. F = Building perimeter that fronts on a public way or open space having a width of 20 feet (6096 mm) or more. Exception: Where a building meets the requirements of Section 507, as applicable, except for compliance with the minimum 60-foot (18 288 mm) public way or yard requirement, and the value of W is greater than 30 feet (9144 mm), the value of W shall not exceed 60 feet (18 288 mm).

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 506.3.2?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters