415.11.1.1.1 Aggregate quantities.
BC § 415.11.1.1.1
The aggregate quantities of hazardous materials stored and used in a single fabrication area shall not exceed the quantities set forth in Table 415.11.1.1.1. Exception: The quantity limitations for any hazard category in Table 415.11.1.1.1 shall not apply where the fabrication area contains quantities of hazardous materials not exceeding the maximum allowable quantities per control area established by Tables 307.1(1) and 307.1(2). Table 415.11.1.1.1Quantity Limits for Hazardous Materials in a Single Fabrication Area in Group H-5 a Hazard CategorySolids(pounds per square foot)Liquids(gallons per square foot)Gas(cubic feet @NTP/square foot)Hazard CategorySolids(pounds per square foot)Liquids(gallons per square foot)Gas(cubic feet @NTP/square foot)Physical-Hazard MaterialsCombustible dustNote bNot ApplicableNot ApplicableCombustible fiber Loose BaledNote bNotes b, cNot ApplicableNot ApplicableCombustible liquid II IIIA IIIBCombination Class I, II and IIIANot Applicable0.010.02Not Limited0.04Not ApplicableCryogenic gas Flammable OxidizingNot ApplicableNot ApplicableNote d1.25ExplosivesNote bNote bNote bFlammable gas Gaseous LiquefiedNot ApplicableNot ApplicableNote dNote dFlammable liquid IA IB ICCombination Class IA, IB and ICCombination Class I, II and IIIANot Applicable0.00250.0250.0250.0250.04Not ApplicableFlammable solid0.001Not ApplicableNot ApplicableOrganic peroxide Unclassified detonable Class I Class II Class III Class IV Class VNote bNote b0.0250.1Not LimitedNot limitedNot ApplicableNot ApplicableOxidizing gas Gaseous LiquefiedCombination of gaseous and liquefiedNot ApplicableNot Applicable1.251.251.25Oxidizer Class 4 Class 3 Class 2 Class 1Combination Class 1, 2, 3Note b0.0030.0030.0030.003Note b0.030.030.030.03Not ApplicablePyrophoric material0.010.00125Notes d and eUnstable reactive Class 4 Class 3 Class 2 Class 1Note b0.0250.1Not LimitedNote b0.00250.01Not LimitedNote bNote bNote bNot LimitedWater reactive Class 3 Class 2 Class 1Note b0.25Not Limited0.001250.025Not LimitedNot ApplicableHealth-Hazard MaterialsCorrosivesNot LimitedNot LimitedNot LimitedHighly toxicNot LimitedNot LimitedNote dToxicsNot LimitedNot LimitedNote d For SI: 1 pound per square foot = 4.882 kg/m2, 1 gallon per square foot = 40.7 L/m2, 1 cubic foot @ NTP/square foot = 0.305 m 3 @ NTP/m2, 1 cubic foot = 0.02832 m 3 a. Hazardous materials within piping shall not be included in the calculated quantities. b. Quantity of hazardous materials in a single fabrication shall not exceed the maximum allowable quantities per control area in Tables 307.1(1) and 307.1(2). c. Densely packed baled cotton that complies with the packing requirements of ISO 8115 shall not be included in this material class. d. The aggregate quantity of flammable, pyrophoric, toxic and highly toxic gases shall not exceed 9,000 cubic feet at NTP. e. The aggregate quantity of pyrophoric gases in the building shall not exceed the amounts set forth in Table 415.6.2.