What is NYC BC § 2603.7.3?

Quick Answer

This section mandates that foam plastic insulation must be covered by corrosion-resistant steel with specific thickness and performance criteria. The covering must have a flame spread index of 75 or less and a smoke-developed index of 450 or less, as tested according to designated standards. Applies to building owners utilizing foam plastic insulation.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2603.7.3 Covering.

BC § 2603.7.3

The foam plastic insulation shall be covered by corrosion-resistant steel having a base metal thickness of not less than 0.0160 inch (0.4 mm) and shall exhibit a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E 84 or UL 723 at the thickness and density intended for use.