What is NYC BC § 2304.11?

Quick Answer

This section outlines the requirements for heavy timber construction, specifying minimum dimensions for structural elements based on their function and configuration. It mandates compliance with detailed tables and provisions regarding lumber decking. Applies to building owners involved in the construction of structures requiring heavy timber elements.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2304.11 Heavy timber construction.

BC § 2304.11

Where a structure, portion thereof or individual structural elements are required by other provisions of this code to be of heavy timber, the building elements therein shall comply with the applicable provisions of Sections 2304.11.1 through 2304.11.4. Minimum dimensions of heavy timber shall comply with the applicable requirements in Table 2304.11 based on roofs or floors supported and the configuration of each structural element, or the applicable requirements in Sections 2304.11.2 through 2304.11.4. Lumber decking shall be in accordance with Section 2304.9. Table 2304.11Minimum Dimensions of Heavy Timber Structural Members SupportingHeavy Timber Structural ElementsMinimum Nominal Solid Sawn SizeMinimum Glued Laminated Net SizeMinimum Structural Composite Lumber Net SizeWidth,InchDepth,InchWidth,InchDepth,InchWidth,InchDepth,InchFloor loads only or combined floor and roof loadsColumns; Framed sawn or glued-laminated timber arches that spring from the floor line; Framed timber trusses886 3/48 1/477 1/2Roof loads onlyWood beams and girders610510 1/25 1/49 1/2Columns (roof and ceiling loads); Lower half of: wood-frame or glued-laminated arches that spring from the floor line or from grade6858 1/45 1/47 1/2Upper half of: wood-frame or glued-laminated arches that spring from the floor line or from grade66565 1/45 1/2Framed timber trusses and other roof framing a ; Framed or glued-laminated arches that spring from the top of walls or wall abutments4 b63 b3 1/2 b5 1/2 For SI: 1 inch = 25.4 mm. a. Spaced members shall be permitted to be composed of two or more pieces not less than 3 inches nominal in thickness where blocked solidly throughout their intervening spaces or where spaces are tightly closed by a continuous wood cover plate of note less than 2 inches nominal in thickness secured to the underside of the members. Splice plates shall be not less than 3 inches nominal in thickness. b. Where protected by approved automatic sprinklers under the roof deck, framing members shall be not less than 3 inches nominal in width.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 2304.11?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters