What is NYC BC § 2113.11.3.2?

Quick Answer

This section mandates that the interior wall of a chimney be lined with approved high-duty refractory brick, at least 4 1/2 inches thick, using high-duty refractory mortar. The lining must extend from the base to the top of the chimney. Applies to building owners responsible for chimney construction and maintenance.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2113.11.3.2 Lining.

BC § 2113.11.3.2

The inside of the interior wall shall be lined with an approved high-duty refractory brick, not less than 4 1/2 inches (114 mm) thick laid on the 4 1/2-inch bed (114 mm) in an approved high-duty refractory mortar. The lining shall start at the base of the chimney and extend continuously to the top.