This section specifies the construction requirements for masonry chimney walls, mandating a minimum thickness of 4 inches for standard walls and 8 inches for walls extending more than 3 feet above the highest lateral support point. Applies to building owners involved in chimney construction and maintenance.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2113.10 Wall thickness.

BC § 2113.10

Masonry chimney walls shall be constructed of concrete, solid masonry units or hollow masonry units grouted solid with not less than 4 inches (102 mm) nominal thickness, or 8 inches (203 mm) nominal thickness for chimney walls extending more than 3 feet (914 mm) above the highest lateral support point.