This section establishes the minimum thickness requirements for hearth extensions, specifying a standard of 2 inches. An exception allows for a reduced thickness of 3/8-inch when the firebox opening is elevated above the hearth extension. Applies to building owners responsible for fireplace installations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

2111.10.2 Hearth extension thickness.

BC § 2111.10.2

The minimum thickness of hearth extensions shall be 2 inches (51 mm). Exception: When the bottom of the firebox opening is raised not less than 8 inches (203 mm) above the top of the hearth extension, a hearth extension of not less than 3/8-inch-thick (9.5 mm) brick, concrete, stone, tile or other approved noncombustible material is permitted.