1708.3.2 Load test procedure not specified.
BC § 1708.3.2
In the absence of applicable load test procedures contained within a standard referenced by this code or acceptance criteria for a specific material or method of construction, such existing structure shall be subjected to a test procedure developed by a registered design professional that simulates applicable loading and deformation conditions. For components that are not a part of the seismic-load-resisting system, the test load shall be equal to two times the unfactored design loads. The test load shall be left in place for a period of 24 hours. The structure shall be considered to have successfully met the test requirements where the following criteria are satisfied: 1. Under the design load, the deflection shall not exceed the limitations specified in Section 1604.3.
2.Within 24 hours after removal of the test load, the structure shall have recovered not less than 75 percent of the maximum deflection.
3.During and immediately after the test, the structure shall not show evidence of failure.