1705.20 Wall panels, curtain walls and veneers.
BC § 1705.20
Special inspection is required for exterior architectural wall panels, curtain walls and the anchoring of veneers for the full height of the installation when any portion of the wall panel, curtain wall and veneer installation exceeds an elevation of 40 feet (12 192 mm) above grade. Special inspection of masonry veneer on such structures shall be in accordance with Section 1705.4. Special inspection of combustible exterior wall covering shall be in accordance with Section 1705.16. Exceptions: Special inspection of wall panels, curtain walls and the anchoring of veneers is not applicable to: 1. Repairs and replacement in kind of gaskets or seals; 2. Reglazing other than 4-sided structural silicone glazing for which a permit is required; or 3. Where exempted by the rules of the department.