1705.16.1 Inspection program.
BC § 1705.16.1
The special inspection shall include verification of compliance with the approved construction documents for the following: attachment to structure; component properties; thicknesses, orientation, cavity sizes and location of thermal barriers, fireblocking and cavity closures; installation of waterproofing membranes, weeps, drains, mold prevention features are as specified; and conformance with the manufacturers' installation instructions, and NFPA 285 tested assembly design documentation. The special inspector shall verify that individual components required to be labeled in accordance with this code do bear such labels.