1619.5.2 Components.
BC § 1619.5.2
The action plan shall, at a minimum, include the following: 1. Threshold of predicted environmental loads; 2. Method of monitoring environmental loads; 3. Name of party responsible for monitoring loads and determining implementation of action plan; 4. Name of party responsible for implementing the action plan; 5. Evacuation procedures; 6. Safety zone, standoff distance or standoff perimeter as appropriate. Safety zone, standoff distance or standoff perimeter shall not extend beyond the property line; 7. Any other activities, such as the addition or removal of structural and/or nonstructural elements, removal of loads or creating sacrificial elements so that the structure may resist unreduced forces as required for permanent structures; 8. Plan to prevent wind-born debris; and 9. Verification that the design and procedures shall not adversely impact other structures.