What is NYC BC § 1609.7.2?

Quick Answer

This section establishes the design wind pressure criteria for canopies attached to walls of buildings exceeding 60 feet in height. The formula provided calculates the pressure based on velocity pressure and a net pressure coefficient. Applies to building owners of tall structures with attached canopies.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1609.7.2 Buildings with h > 60 ft.

BC § 1609.7.2

The design wind pressure for canopies attached to walls of buildings with h > 60 ft. and hc/h < 0.5, as shown on Figure 1609.7, shall be from the following equation: P = qh(GCpn) (lb/ft 2 ) (Equation 16-42) Where: qh = velocity pressure at mean roof height h per Chapter 26 of ASCE 7. GCpn = net pressure coefficient for attached canopies given in Table 1609.7.