1607.15.1 Fabric partitions.
BC § 1607.15.1
Fabric partitions that exceed 6 feet (1828.8 mm) in height, including their finish materials, shall have adequate strength and stiffness to resist the following load conditions: 1. The horizontal distributed load need only be applied to the partition framing. The total area used to determine the distributed load shall be the area of the fabric face between the framing members to which the fabric is attached. The total distributed load shall be uniformly applied to such framing members in proportion to the length of each member.
2.A concentrated load of 40 pounds (0.176 kN) applied to an 8-inch diameter (203.2 mm) area of the fabric face at a height of 54 inches (1371.6 mm) above the floor.