1511.3.1 Roof recover.
BC § 1511.3.1
The installation of a new roof covering over an existing roof covering shall be permitted where any of the following conditions occur: 1. Where the new roof covering is installed in accordance with the roof covering manufacturer's instructions.
2.Complete and separate roofing systems, such as standing-seam metal roof panel systems, that are designed to transmit the roof loads directly to the building's structural system and that do not rely on existing roofs and roof coverings for support, shall not require the removal of existing roof coverings.
3.Metal panel, metal shingle and concrete and clay tile roof coverings shall be permitted to be installed over existing wood shake roofs when applied in accordance with Section 1511.4.