1407.1.2 Prohibited locations.
BC § 1407.1.2
The use of MCM in exterior wall coverings is subject to the following limitations: 1. MCM is prohibited in exterior wall coverings in Type IV construction utilizing cross-laminated timer (CLT) or structural composite lumber (SCL) complying with Section 602.4.
2.MCM is prohibited in exterior wall coverings at exterior balconies in accordance with Section 1406.3.