This section mandates that multiple dwellings of five or more stories with nine or more units must include a refuse chute, access rooms, and a termination room, with specific requirements for recyclable material storage. Exceptions apply for buildings without elevators and certain transient hotels. Applies to building owners of qualifying multiple dwellings.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1213.3 Refuse chute.

BC § 1213.3

A multiple dwelling that is five or more stories in height and that contains 9 or more dwelling units shall be provided with a refuse chute, chute access rooms, and refuse chute termination room constructed in accordance with Section 713.13. A minimum of 5 square feet (0.470 m 2 ) of floor area within each refuse chute access room shall be provided for the temporary holding of recyclables. Such floor area shall be clearly identified on the construction documents. In Group I-1 and R-1 occupancies, access to the chute access room shall be permitted to be restricted to employees provided that separate refuse storage rooms are located on each story for general occupant use. Exceptions: 1. In buildings without an elevator, floor area within refuse chute access rooms for the temporary holding of recyclables is not required.

2.In buildings equipped with separate chutes designated for refuse, for paper and cardboard, and for metal, glass and plastic, and in buildings equipped with a chute system that provides for source separation of recyclable materials without cross contamination, floor area within refuse chute access rooms for the temporary holding of recyclables is not required. Chutes for designated recyclable materials shall be constructed in accordance with Section 713.13 of this code.

3.The refuse chute and the occupant use storage rooms shall not be required in transient hotels meeting the following requirements: 3.1 the refuse is removed from rooms by a daily cleaning service, with the staff using a service elevator that is not accessed by hotel guests; 3.2 the building is of Type I or Type II construction; or 3.3 a compactor and refuse storage room is provided in accordance with Section 1213.2. Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2012/060.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 1213.3?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters