What is NYC BC § 1029.19.3.2?

Quick Answer

This section mandates that safe areas in places of assembly be artificially illuminated by electrical means during occupancy. The required illumination level is at least 5 footcandles (54 lux) on the floor and surfaces of stairs, steps, ramps, and escalators. Applies to building owners of assembly venues.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1029.19.3.2 Safe area lighting.

BC § 1029.19.3.2

In addition to requirements of Section 1008, safe areas shall be artificially lighted by electrical means at all times during occupancy of a place of assembly so as to provide illumination of at least 5 footcandles (54 lux) at the level of the floor and on the surface of all stairs, steps, ramps, and escalators within the safe area.