This section establishes requirements for guard openings to prevent the passage of spheres of specified diameters, ensuring safety at various heights and in different occupancy types. The Department of Buildings enforces these regulations. Applies to building owners and property operators responsible for guard installations and safety compliance.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1015.4 Opening limitations.

BC § 1015.4

Required guards shall not have openings that allow passage of a sphere 4 inches (101.6 mm) in diameter from the walking surface to the required guard height. Exceptions: 1. From a height of 36 inches (914.4 mm) to 42 inches (1066.8 mm), guards shall not have openings that allow passage of a sphere 4 3/8 inches (111.1 mm) in diameter.

2.The triangular openings at the open sides of a stair, formed by the riser, tread and bottom rail shall not allow passage of a sphere 6 inches (152.4 mm) in diameter.

3.At elevated walking surfaces that are not open to the public for access to and use of electrical, mechanical or plumbing systems or equipment, guards shall not have openings that allow passage of a sphere 21 inches (533.4 mm) in diameter.

4.In areas that are not open to the public within occupancies in Group I-3, F, H or S, and for alternating tread devices and ships ladders, guards shall not have openings that allow passage of a sphere 21 inches (533.4 mm) in diameter.

5.In assembly seating areas, guards required at the end of aisles in accordance with Section 1029.16.4 shall not have openings that allow passage of a sphere 4 inches (101.6 mm) in diameter up to a height of 26 inches (660.4 mm). From a height of 26 inches (660.4 mm) to 42 inches (1066.8 mm) above the adjacent walking surfaces, guards shall not have openings that allow passage of a sphere 8 inches (203.2 mm) in diameter.

6.Within individual dwelling units and sleeping units in Group R-2 and R-3 occupancies, guards on the open sides of stairs shall not have openings that allow passage of a sphere 4 3/8 inches (111.1 mm) in diameter.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 1015.4?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters