1010.1.2.1 Mounting.
BC § 1010.1.2.1
Egress doors shall be of the pivoted or side-hinged swinging type. Exceptions: 1. Private garages, office areas, factory and storage areas with an occupant load of 10 or less.
2.Group I-3 occupancies used as a place of detention.
3.Critical or intensive care patient rooms within suites of health care facilities.
4.Doors within or serving a single dwelling unit in Groups R-2 and R-3.
5.In other than Group H occupancies, revolving doors complying with Section 1010.1.4.1.
6.In other than Group H occupancies, special purpose horizontal sliding, accordion or folding door assemblies complying with Section 1010.1.4.3.
7.Power-operated doors in accordance with Section 1010.1.4.2.
8.Doors serving a bathroom within an individual sleeping unit in Group R-1.
9.In other than Group H occupancies, manually operated horizontal sliding doors are permitted in a means of egress from spaces with an occupant load of 10 or less.