§ 1-84 Small Asbestos Project Worker and Waste Decontamination Enclosure System.
RCNY § 1-84
The following alternative to 15 RCNY §§ 1-82 and 1-83 shall be applicable for small projects only: (a) The worker decontamination enclosure system shall consist of, as a minimum, an equipment room, a shower room, and a clean room separated from each other and from the work area by curtained doorways. Equipment storage, personal gross decontamination and removal of disposable clothing shall occur in the equipment room prior to entering the shower. All other requirements set forth in 15 RCNY § 1-82 and 15 RCNY § 1-92 shall apply.