This section outlines the requirements for glass panels subject to human impact loads, including specifications for thickness and protective measures. Compliance with table 10-9 is necessary for various types of glass in specific installations. Applies to building owners and property operators responsible for maintaining safety standards in glass installations.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

§ 27-651 Panels subject to human impact loads.

AC § 27-651

Glass in prime and storm doors, interior doors, fixed glass panels that may be mistaken for means of egress or ingress, shower doors and tub enclosures, or in similar installations wherein one or more of the following criteria apply, shall meet the requirements set forth in table 10-9, or by comparative tests shall be proven to produce equivalent performance: (a) openings are located in regularly occupied spaces.

(b)lowest point of panel is less than eighteen inches above finished floor.

(c)minimum dimension of panel is larger than eighteen inches. Table 10-9Requirements for Glass Panels Subject to Impact Loads a, b Glass Type Individual Opening AreaRequirementsRegular plate, sheet or rolled (annealed)Over 6 sq. ft. Not less than 3/16 in. thick. Must be protected by a push-bar or protective grille firmly attached on each exposed side c, if not divided by a muntin.Regular plate, sheet or rolled (annealed), surface sandblasted, etched, or otherwise depreciatedOver 6 sq. ft. Not less than 7/32 in. thick. Must be protected by a push-bar or protective grille firmly attached on each exposed side c.Regular plate, sheet or rolled (annealed), obscureOver 6 sq. ft. Not less than 3/16 in. thick. Must be protected by a push-bar or grille firmly attached on each exposed side c.LaminatedOver 6 sq. ft. Not less than 1/4 in. thick. Shall pass impact test requirements of reference standard RS 10-67.Fully-temperedOver 6 sq. ft. Shall pass impact test requirements of reference standard RS 10-67.WiredOver 6 sq. ft. Not less than 7/32 in. thick. Shall pass impact test requirements of reference standard RS 10-67.All unframed glass doors (swinging) Shall be fully-tempered glass and pass impact test requirements of reference standard RS 10-67. NOTES: a Glass less than single strength (SS) in thickness shall not be used. b If short dimension is larger than 24 in., glass must be double strength (DS) or thicker. c Building owners and tenants shall maintain push-bars or protective grilles in safe condition at all times.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 27-651?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters