This section mandates that door openings must have a minimum clear width of 32 inches for occupant safety, with specific exceptions for certain occupancy types and conditions. The statute is enforced by the Department of Buildings (DOB). Applies to building owners and operators responsible for compliance with egress requirements.

General informational summary. Not legal advice for your situation. Consult an attorney before acting on any specific matter.

Michael Nacmias - Founding PartnerMichael Sargo - Partner
From the team atNacmias Law Firm, PLLCBrooklyn-based attorneys representingproperty owners across all five boroughsMeet the team →

1010.1.1.1 Door width.

BC § 1010.1.1.1

The required capacity of each door opening shall be sufficient for the occupant load thereof and shall provide a minimum clear width of 32 inches (812.2 mm). Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear width of 32 inches (812.8 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches (812.8 mm). The maximum width of a swinging door leaf shall be 48 inches (1220 mm) nominal. Means of egress doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 41 1/2 inches (1054.1 mm). Exceptions: 1. The minimum and maximum width shall not apply to door openings that are not part of the required means of egress in Group R-2 and R-3 occupancies.

2.Door openings to resident sleeping units in Group I-3 occupancies shall have a clear width of not less than 28 inches (711.2 mm).

3.Door openings to storage closets less than 10 square feet (0.93 m 2 ) in area shall not be limited by the minimum width.

4.Width of door leaves in revolving doors that comply with Section 1010.1.4.1 shall not be limited.

5.In other than Group R-1 occupancies, the minimum widths shall not apply to interior egress doors within a dwelling unit or sleeping unit that is not required to be an Accessible unit, Type B+NYC or Type B unit.

6.Doors to walk-in freezers and coolers less than 1,000 square feet (92.9 m 2 ) in area shall have a maximum width of 60 inches (1524 mm).

7.In Group R-1 dwelling units or sleeping units not required to be Accessible units, the minimum width shall not apply to doors for showers or saunas.

Common Questions

Our team

Meet the people you will work with

Free case review

Have a matter that touches § 1010.1.1.1?

Free 15-minute case review with the attorney handling your matter. Same-day response during business hours across all five boroughs — OATH hearings, Housing Court, and real estate closings.

Or email us

[email protected]

An attorney reads every message.

  • Same-day response

    During business hours

  • Direct attorney access

    Same lawyer from intake to close

  • Flat-fee pricing

    On most OATH and closing matters